Exclusive SALE Offer Today

What Are Two Elements That Form the PRI Value in a Syslog Message? (Choose Two.) - Syslog Explained

10 Apr 2025 Cisco
What Are Two Elements That Form the PRI Value in a Syslog Message? (Choose Two.) - Syslog Explained

Introduction

Syslog is a widely used standard for managing and transmitting log data in networking and IT environments. By capturing, storing, and forwarding log information, syslog helps IT professionals troubleshoot problems, monitor network security, and maintain system performance. One of the core components of a syslog message is its PRI value, which plays a vital role in identifying the severity and facility of the message. In this blog, we will delve into the two essential elements that form the PRI value in a syslog message and their significance in understanding syslog data. When you're working with syslog messages, particularly in environments that require effective system monitoring and analysis, it is important to comprehend how these messages are constructed. The PRI value, which is located at the beginning of each syslog message, is composed of two elements: Facility and Severity. Understanding these components will allow you to better interpret syslog data, analyze potential issues, and implement security measures effectively.

What is a Syslog Message?

Before diving into the details of the PRI value, it is essential to understand what a syslog message consists of. A syslog message generally has the following structure:

  1. PRI Value: Contains the facility and severity of the message.

  2. Timestamp: Indicates when the event occurred.

  3. Hostname: The name of the system that generated the message.

  4. Message Content: The actual log message that provides details about the event.

The PRI value, located at the very start of the message, is crucial for differentiating between various types of logs. It allows systems and administrators to quickly assess the importance and type of event being logged.

Facility: Understanding the Core Context of a Syslog Message

The Facility element within the PRI value is responsible for identifying which part of the system or application generated the log message. It is essentially a code that designates the type of software or hardware responsible for the message. The facility value ranges from 0 to 23, each representing a different system or application.

Common Facility Values

  • 0 (kern): Kernel messages

  • 1 (user): User-level messages

  • 2 (mail): Mail system messages

  • 3 (daemon): System daemons

  • 4 (auth): Security/authorization messages

  • 6 (lpr): Line printer system messages

  • 7 (news): Usenet news system messages

  • 10 (cron): Cron daemon messages

  • 16 (local0): Local use 0

  • 23 (local7): Local use 7

By specifying a particular facility, syslog messages help administrators easily categorize logs based on the type of service or application generating the event.

The Role of Facility in Troubleshooting

The facility value plays a key role in troubleshooting. For example, when investigating a system failure or network issue, you can filter syslog messages by their facility values. If you are looking for kernel-related issues, you would focus on logs that have a facility value of 0 (kern). Similarly, if you want to investigate security-related issues, you would filter logs with a facility value of 4 (auth). This facility information can significantly streamline the process of pinpointing the source of a problem. Administrators can also set up alerts based on specific facility values, ensuring that critical messages are highlighted for immediate attention.

Severity: Understanding the Level of Importance

The Severity element in the PRI value represents the importance or severity level of the event being logged. The severity value ranges from 0 to 7, with 0 being the highest level (emergency) and 7 being the lowest (debug). Severity helps administrators prioritize their responses based on the criticality of the message.

Common Severity Levels

  • 0 (Emergency): System is unusable; requires immediate attention.

  • 1 (Alert): A critical issue that needs to be addressed as soon as possible.

  • 2 (Critical): A significant problem that needs to be addressed promptly.

  • 3 (Error): A non-critical error that may cause problems.

  • 4 (Warning): A potential issue that may need attention in the future.

  • 5 (Notice): Informational messages that do not indicate a problem.

  • 6 (Informational): Regular operational messages that provide updates.

  • 7 (Debug): Detailed debugging information used for troubleshooting.

The Role of Severity in Incident Response

Severity values are crucial for incident response. When a syslog message is generated, the severity value helps the system or administrator prioritize actions. For instance, if a syslog message has a severity value of 0 (emergency), this indicates that the system is in a critical state and requires immediate attention. On the other hand, a severity value of 7 (debug) might simply indicate that detailed information is being logged for troubleshooting purposes and does not require urgent intervention. By categorizing logs according to severity, system administrators can filter out non-critical messages and focus their efforts on resolving high-priority issues first. Additionally, automated monitoring systems can be set to trigger alerts or notifications for specific severity levels, ensuring that critical issues are immediately addressed.

Combining Facility and Severity to Form the PRI Value

The PRI value in a syslog message is a combination of the Facility and Severity elements. To calculate the PRI value, the following formula is used: PRI=(Facility×8)+Severity\text{PRI} = (\text{Facility} \times 8) + \text{Severity}For example, if the Facility value is 1 (user-level messages) and the Severity value is 3 (error), the PRI value would be calculated as follows: PRI=(1×8)+3=11\text{PRI} = (1 \times 8) + 3 = 11This PRI value (11) is then included at the beginning of the syslog message, allowing systems and administrators to immediately know the type of message (facility) and its importance (severity).

Example Syslog Message Breakdown

Let’s consider an example of a syslog message to better understand how the PRI value works:

<11>Oct 18 14:22:35 server1 sshd[1234]: Failed password attempt from 192.168.1.100

  • PRI Value: <11> – The PRI value is 11, which corresponds to a facility value of 1 (user-level messages) and a severity value of 3 (error).

  • Timestamp: Oct 18 14:22:35 – The date and time the event occurred.

  • Hostname: server1 – The system where the log was generated.

  • Message: Failed password attempt from 192.168.1.100 – The content of the log, which provides details about the event.

In this example, the syslog message indicates an error in the user-level application (sshd) involving a failed password attempt.

How to Analyze Syslog Messages

When analyzing syslog messages, the PRI value helps identify the criticality and source of the issue. Here’s how you can leverage the PRI value for effective analysis:

  1. Filter by Facility: Focus on specific areas of the system, such as kernel, user-level applications, or network services.

  2. Prioritize by Severity: Respond to high-severity messages first, such as emergencies and alerts, while low-severity messages can be addressed later or archived for future reference.

  3. Set up Alerts: Configure your syslog server or monitoring tool to trigger alerts for specific facility or severity levels, ensuring that you are notified of critical issues in real-time.

Practical Application: Configuring Syslog Servers

Syslog servers often allow administrators to configure filters based on the PRI value. For example, you can configure a syslog server to forward all messages with a severity level of 0 (emergency) or 1 (alert) to a dedicated administrator’s email or SMS. Similarly, low-severity messages (such as debug messages) can be logged into a separate file for later review. By using the facility and severity values in syslog messages, syslog servers can efficiently organize logs and ensure that critical events are promptly addressed.

Conclusion

Understanding the two elements that form the PRI value in a syslog message facility and severity is essential for anyone working with network systems, security, or monitoring. The PRI value helps categorize syslog messages, allowing IT professionals to filter, prioritize, and analyze logs more effectively. By correctly interpreting the PRI value, you can streamline troubleshooting, enhance incident response, and better maintain the security and health of your network infrastructure. As you dive deeper into the world of syslog and network management, remember that the PRI value is just one of many tools that will help you keep your systems running smoothly. At DumpsQueen, we offer certifications and learning materials that can help you master syslog and other essential networking concepts to excel in your IT career.

 Free Sample Question 

  1. What is the formula used to calculate the PRI value in a syslog message? a) PRI = (Facility + Severity)
    b) PRI = (Facility * 8) + Severity
    c) PRI = (Facility / 8) + Severity
    d) PRI = (Severity * 8) + Facility

    Answer: b) PRI = (Facility * 8) + Severity

  2. Which severity value represents a debug message in a syslog? a) 0
    b) 3
    c) 6
    d) 7

    Answer: d) 7

  3. Which facility value corresponds to security-related messages in a syslog? a) 0 (kern)
    b) 4 (auth)
    c) 6 (lpr)
    d) 10 (cron)

    Answer: b) 4 (auth)

Limited-Time Offer: Get an Exclusive Discount on the  200-301 EXAM DUMPS – Order Now!

How to Open Test Engine .dumpsqueen Files

Use FREE DumpsQueen Test Engine player to open .dumpsqueen files

DumpsQueen Test Engine

Windows

 safe checkout

Your purchase with DumpsQueen.com is safe and fast.

The DumpsQueen.com website is protected by 256-bit SSL from Cloudflare, the leader in online security.

Need Help Assistance?